6 building in – AEG HG795440NB User Manual

Page 14

Advertising
background image

A

B

C
D

E

A)

Green and Yellow

B)

3 amp fuse

C)

Brown

D)

Cord clamp

E)

Blue

The wires in the cord are coloured as fol-
lows:

Green and yellow

- Earth

Blue

- Neutral

Brown

- Live

Replacement of the connection cable

1.

Connect the green and yellow
(earth) wire to the terminal which is
marked with the letter 'E', or the
earth symbol

, or coloured green

and yellow.

2.

Connect the blue (neutral) wire to
the terminal which is marked with
the letter 'N' or coloured blue.

3.

Connect the brown (live) wire to the
terminal which is marked with the

letter 'L'. It must always be connec-
ted to the network phase.

There must be no cut or stray strands of
wire present. The cord clamp must be
correctly attached to the outer sheath.

To replace the connection cable
use only H05V2V2-F T90 or
equivalent type. Make sure that
the cable section is applicable to
the voltage load and the working
temperature. The yellow/green
earth wire (B) must be approxi-
mately 2 cm longer than the live
and neutral wire (A).

A

B

WARNING!
A cut off plug inserted into a 13
amp socket is a serious safety
(shock) hazard. Ensure that the
cut off plug is disposed of safely.

The replacement of electric cable
must be carried out exclusively
by the service force centre or by
personnel with similar competen-
cies, in accordance with the cur-
rent regulations.

8.6 Building In

min. 55 mm

min. 650 mm

560 mm

min. 450 mm

30 mm

480 mm

min. 600 mm

A

14 www.aeg.com