Technical Information
DIMENSIONS

HEIGHT (CANOPY):

60 mm

HEIGHT (CHIMNEY):

695 - 415 mm

WIDTH (CANOPY):

998 mm

WIDTH (CHIMNEY):

350 mm

GROSS:

19,5 kg - 20 kg

NET:

15,5 kg - 17,2 kg

ELECTRICAL SUPPLY:

220-240 V (50 Hz)

POWER CONSUMPTION:

285 W

FAN MOTOR:

260 W

LAMP:

(4x4W) Led

16 W

SUITABLE FOR INSTALLATION
ABOVE:

ELECTRIC HOB:

7 KW

GAS HOB:

10 KW

SLOT-IN GAS COOKER

13.5 KW

SLOT-IN ELECTRIC COOKER

12.4 KW

Note: CE Marking certifies that this appliance complies with the requirements laid down

in EEC directive 89:336. (Electromagnetic compatibility) and subsequent modifications
and Low Voltage directive 72/23/E.

ELECTRICAL CONNECTIONS

This appliance must be earthed

Electrical Requirements

Any permanent electrical installation must comply with

the latest I.E.E. Regulations and local Electricity Board

regulations. For your own safety this should be under-

taken by a qualified electrician e.g. your local Electricity

Board, or a contractor who is on the roll of the National

Inspection Council for Electrical Installation Contracting

(NICEIC).

Electrical Connection

Before connecting to the mains supply ensure that the

mains voltage corresponds to the voltage on the rating

plate inside the cooker hood.

Remove the grease filters (see paragraph Maintenance)

being sure that the connector of the feeding cable is

correctly inserted in the socket placed on the side of

the fan.

This appliance is fitted with a 3 core mains cable and

must be permanently connected to the electricity supply

via a double-pole switch having 3mm minimum contact

gap on each pole. A Switched Fuse Connection Unit to

BS1363 Part 4, fitted with a 3 Amp fuse, is a recom-

mended mains supply connection accessory to ensure

compliance with the Safety Requirements applicable to

fixed wiring instructions.

This appliance conforms to BS 800: 1988 and EEC

Directive No. 78 308 regarding suppression of radio and

television interference.