AEG AIR AND POWER STATION LA 10 User Manual

Page 25

Advertising
background image

The compressor is switched on
but not functioning.

The operating switch is not
activated.

Activate the unit's operating
switch before using the
compressor.

Charge the storage battery using
the 230 V charging mains
adapter.

When switching on the operating
switch the LEDs and manometer
lighting do not light up. The
storage battery is empty.

Replace the defective 15 A flat
fuse with a new fuse.

The 15 A fuse is defective.

The storage battery is fully
charged and the fuse is good,
but the unit isn't functioning.

The unit is defective.

Please consult a qualified
professional.

The compressor is overheated.

The compressor was operated for
more than 10 minutes.

Allow the unit to cool down for
10 minutes and follow the max.
operating cycle of 10 minutes of
operation and 10 minutes of cool
down.

The vents on the unit are covered
by an object or blocked.

Remove the object from the unit's
vents or clean the vents.

The compressor loses pressure
and does not build enough air
pressure.

The compressed air hose or
the compressor is leaking or
damaged.

Please consult a qualified
professional.

The valve adapter or the
automotive valve connector is
not

attached.

correctly

Verify the valve adapter is
correctly attached to the automo-
tive valve connector and in the
item's valve. Verify the automo-
tive valve connector is correctly
seated on the tyre valve.

13

13

If you are unable to resolve the malfunction with
the actions described, please consult a qualified
professional.

The above table on troubleshooting and possible
causes and their repair does not indicate all
possible errors.

Solutions, repair

Possible causes

Error / Malfunction

4.7 Troubleshooting

GB

25

97180_Luft-Energiestation_LA_10_Manual _01_08_2012_print

Mittwoch, 1. August 2012 12:30:07

Advertising