OPERATION

Before charging batteries

▪

If the battery must be removed from the vehicle before charging, always discon-
nect the earthed connector from the battery first. Also ensure all other loads in
the vehicle are off.

▪

Ensure adequate ventilation to allow any toxic vapours or gasses to disperse.

▪

Ensure the battery poles are clean. If the battery has a removable vent cap, fill
each battery cell with distilled water to the manufacturer recommended level. Do
not overfill the cells.

▪

If the battery does not have caps, refer to the manufacturer instructions on char-
ging and the charging speed.

Connecting the battery

Risk of electrical shock!
Always verify the charging device is disconnected from the 230 V AC
outlet when connecting to a battery..

▪

Always ensure the area around the battery is well ventilated during the charging
process.

1. Before connecting verify the switch is set to the desired voltage:

▪

12 V

▪

24 V

2. Connect the positive charging clamp (red) to the positive battery terminal

(marked P or +).

3. Connect the negative charging clamp (black) to the body of the vehicle, or in

exceptions to the negative battery terminal (marked N or -).

4. Verify both terminal clamps make good contact with the respective terminals.
5. Plug the power plug into a suitable AC mains outlet