CLEARANCES FOR MODEL 94NC

MINIMUM CLEARANCES TO COMBUSTIBLES

RESIDENTIAL SINGLE WALL CONNECTOR



Figure 13




A

B

C

D

E F

G H


MODEL 94NC

25"

8" 10.5" 8"

8"

6" 20" 10”


NOTE: All clearances are to combustibles using single wall pipe, minimum floor protector.

Minimum floor protection under unit must have an R-value of 0.30. (see page 12, 13)

NOTE: The clearances above may be reduced, follow NFPA-211 codes.

For wall exit, Floor protector must be under horizontal pipe the length between stove
and exit. Must be 2” on each side of pipe. Maintain 18" between pipe and ceiling.
(See Figure 13, measurements F & H ).

BACK WALL

SIDE WAL

L

A

E

B

F

C

C

D

G

D

D

C

G

B

C

F

A

E

H

22” 23” 26” 23” 8” 6” 16” 12”