Cleaning the Mouse Ball

If dirt or foreign subject is stuck to the mouse ball, the ball may not roll smoothly, causing difficulty in moving the
electronic pointer. In such a case, clean the ball as described below.

1

Unlock the frame at the bot-
tom of the mouse and re-
move the ball.

Using a pointed tool, turn the two guide holes of
the frame in the direction of the arrow (to the
left) to release the lock.
Be careful not to drop the ball.

2

Wipe off the contamination
from the ball’s surface.

Wipe away stains with a clean dry cloth.
For stubborn stains, soak a soft cloth with a
neutral detergent and thoroughly wipe the ball
surface of the ball.

3

Clean the ball support and
roller block.

Using a cotton swab, lightly wipe the block and
while rotating the rollers.

4

Mount the ball and lock the
frame.

Insert the ball into the mouse. Attach the frame
and turn it to the right using a pointed tool to lock.

MAINTENANCE

1

Turn the power off at the
POWER switch, and discon-
nect the power plug from the
AC outlet.

Soon after the lamp was lit, wait for 15 minutes or
more for the lamp to cool down.

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Replacing the Fluorescent Lamps

The fluorescent lamps used with this unit are commercially available. When a lamp has burned out, purchase one by
specifying the type name (FPL13EX-N).

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Cleaning the Main Unit

To remove dirt from the cabinet, lightly wipe the surface with a soft cloth.
For adhered dirt, wipe with a cloth soaked with neutral detergent diluted with water and wrung tight. Then wipe the
surface with a dry cloth.

Rotate the lamp holder up-
wards, and remove the fluo-
rescent lamp.

As the fluorescent lamp may be hot, we suggest
wearing gloves.

2

Glove

While pressing the lamp to-
wards the socket, fit it in the
holder.

A clicking sound is heard.

If no clicking sound is heard,
press the holder with your fingers.

4

Replace the lamp on the other
side in the same manner.

5

Caution

[

Before replacing a lamp, wait at least 15 minutes for it to sufficiently cool down to avoid

burning your fingers.

[

NEVER apply excessive force to a tube. It may break, causing injury.

[

Replacement of the fluorescent lamp under the document stage must be referred to your

dealer. Never attempt to replace it yourself.

Insert the new fluorescent
lamp into the socket.

3

[

Be careful that the lamp will not be dam-

aged by the holder.

[

Make sure that the lamp is firmly secured

in the socket and holder.

Note

Caution for

replacement

Do NOT replace

it yourself

**BARCO 038-043(E)

2000.7.18, 8:19 PM

38-39