To switch on, press the room

temperature switch, Fig. "/B. Red mark

becomes visible. The light inside the

appliance is lit at a reduced luminosity.
To save energy, switch off the room

temperature switch as soon as the room

temperature exceeds +16 °C.

Ventilation

Fig. !/6
The refrigeration unit is ventilated only via

the ventilation grille in the base. Never

cover the ventilation grille or place

anything in front of it. Otherwise the

refrigeration unit must work harder,

increasing the power consumption.

Installation location

Install the appliance in a dry, well

ventilated room. The installation location

should neither be exposed to direct

sunlight nor near a heat source, e. g. a

cooker, radiator, etc. If installation next to

a heat source is unavoidable, use a

suitable insulating plate or observe the

following minimum distances to a heat

source:

3 cm to electric or gas cookers.

30 cm to an oil or coal-fired cooker.

Undercounter

An attachment under certain worktops,

e.g. stone, glass or stainless steel, is

frequently not possible. You can order

accessories from customer service for

installation on the side walls.

Connecting the

appliance

After installing the appliance, wait at least

1 hour until the appliance is switched on.

During transportation the oil in the

compressor may have flowed into the

refrigeration system.
Before switching on the appliance for the

first time, clean the interior of the

appliance (see chapter “Cleaning the

appliance”).

Electrical connection

The socket must be near the appliance

and also freely accessible following

installation of the appliance.
The appliance complies with the

protection class I. Connect the appliance

to 220–240 V/50 Hz alternating current

via a correctly installed socket with

protective conductor. The socket must

be fused with a 10 to 16 A fuse.
For appliances operated in non-

European countries, check whether the

stated voltage and current type match

the values of your mains supply. This

information can be found on the rating

plate. Fig. .