Bryant Induced-Combustion 4-Way Multipoise 310AAV User Manual

Page 39

Advertising
background image

The inducer and blower motors are pre-lubricated and require no
additional lubrication. These motors can be identified by the
absence of oil ports on each end of the motor.

Clean blower motor and wheel as follows:

1. Turn off electrical supply to furnace.

2. Loosen the thumbscrew on outer door and remove outer door.

3. For downflow or horizontal furnaces having vent pipes within

the furnace that pass in front of the blower access door:

a. Disconnect vent connector from furnace vent elbow.

b. Disconnect and remove short piece of vent pipe from

within furnace.

TABLE 12—Orifice Size* and Manifold Pressure For Gas Input Rate

(Tabulated Data Based On 22,000 Btuh Per Burner, Derated 4 Percent For Each 1000 Ft Above Sea Level)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

0

to

2000

900

42

3.5

42

3.6

42

3.7

41

3.5

925

42

3.3

42

3.4

42

3.5

42

3.7

950

43

3.8

42

3.3

42

3.4

42

3.5

975

43

3.6

43

3.8

42

3.2

42

3.3

1000

43

3.5

43

3.6

43

3.7

43

3.8

1025

43

3.3

43

3.4

43

3.5

43

3.6

1050

44

3.6

43

3.2

43

3.4

43

3.5

1075

44

3.4

44

3.5

43

3.2

43

3.3

1100

44

3.3

44

3.4

44

3.5

43

3.2

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

U.S.A.

Altitudes

2001

to

3000

or

Canada

Altitudes

2000

to

4500

800

42

3.4

42

3.5

42

3.6

42

3.7

825

42

3.2

42

3.3

42

3.4

42

3.5

850

43

3.7

43

3.8

42

3.2

42

3.3

875

43

3.5

43

3.6

43

3.7

43

3.8

900

43

3.3

43

3.4

43

3.5

43

3.6

925

43

3.1

43

3.2

43

3.3

43

3.4

950

43

2.9

43

3.0

43

3.1

43

3.2

975

43

2.8

43

2.9

43

3.0

43

3.1

1000

43

2.6

43

2.7

43

2.8

43

2.9

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A. Only

3001

to

4000

775

42

3.2

42

3.3

42

3.4

42

3.5

800

43

3.6

43

3.8

42

3.2

42

3.3

825

43

3.4

43

3.5

43

3.7

43

3.8

850

43

3.2

43

3.3

43

3.4

43

3.6

875

43

3.0

43

3.1

43

3.3

43

3.4

900

43

2.9

43

3.0

43

3.1

43

3.2

925

43

2.7

43

2.8

43

2.9

43

3.0

950

43

2.6

43

2.7

43

2.8

43

2.8

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

4001

to

5000

750

43

3.6

43

3.8

42

3.2

42

3.3

775

43

3.4

43

3.5

43

3.6

43

3.8

800

43

3.2

43

3.3

43

3.4

43

3.5

825

43

3.0

43

3.1

43

3.2

43

3.3

850

43

2.8

43

2.9

43

3.0

43

3.1

875

43

2.7

43

2.8

43

2.9

43

2.9

900

43

2.5

43

2.6

43

2.7

43

2.8

925

43

2.4

43

2.5

43

2.6

43

2.6

* Orifice numbers 43 are factory installed

38

Advertising