Electrical requirements – Whirlpool WED7500VW User Manual

Page 10

Advertising
background image

10

Installation spacing for recessed area

or closet installation

n

All dimensions show recommended and minimum spacing

allowed.

n

Additional spacing should be considered for ease of

installation and servicing.

n

Additional clearances might be required for wall, door, floor

moldings, and dryer venting.

n

Additional spacing should be considered on all sides of the

dryer to reduce noise transfer.

n

For closet installation with a door, minimum ventilation

openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are

acceptable.

n

Companion appliance spacing should also be considered.

1"

(25 mm)

3"

(76 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

1"

(25 mm)

9"

(229 mm)

18" min

(457 mm)

Recessed or closet installation (dryer only):

Mobile home - Additional installation requirements:

This dryer is suitable for mobile home installations.

The installation must conform to the Manufactured

Home Construction and Safety Standard, Title 24 CFR,

Part 3280 (formerly the Federal Standard for Mobile home

construction and Safety, Title 24, HUD Part 280).

Mobile home installations require:

n

Metal exhaust system hardware, available for purchase

from your dealer.

n

Special provisions must be made in mobile homes to

introduce outside air into dryer. Openings (such as a nearby

window) should be at least twice as large as dryer exhaust

opening.

Custom undercounter installation (dryer only):

1"

(25 mm)

1"

(25 mm)

33

1

/

4

"

(845 mm)

23

3

/

8

"

(594 mm)

1"

(25 mm)

5

1

/

4

"

(133 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

66

1

/

4

"

(1683 mm)

12"

(305 mm)

1"

(25 mm)

Recessed or closet installation –

Stacked with stack kit:

ELECTRICAL REQUIREMENTS

It is your responsibility:

n

To contact a qualified electrical installer.

n

To be sure that the electrical connection is adequate and in

conformance with the National Electrical Code, ANSI/NFPA

70 – latest edition and all local codes and ordinances.

The National Electrical Code requires a 4-wire power supply

connection for homes built after 1996, dryer circuits involved

in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from:

National Fire Protection Association, One Batterymarch

Park, Quincy, MA 02269.

n

To supply the required 3 or 4 wire, single phase, 120/240

volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208

volt electrical supply, if specified on the serial/rating plate)

on a separate 30-amp circuit, fused on both sides of the

line. Connect to an individual branch circuit. Do not have

a fuse in the neutral or grounding circuit.

n

Do not use an extension cord.

n

If codes permit and a separate ground wire is used, it is

recommended that a qualified electrician determine that

the ground path is adequate.

Advertising