Install vent system, Connect vent, Vent system chart – Whirlpool WED7500VW User Manual

Page 18

Advertising
background image

18

Vent System Chart

Number of

90° elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

2

0

Rigid metal

Rigid metal

Rigid metal

90 ft. (27.4 m)

80 ft. (24.4 m)

70 ft. (21.3 m)

80 ft. (24.4 m)

70 ft. (21.3 m)

60 ft. (18.3 m)

The “Vent System Chart” provides venting requirements that

will help achieve best drying performance.

Special provisions for mobile homes:

Exhaust vent must be securely fastened to a noncombustible

portion of mobile home and must not terminate beneath the

mobile home. Terminate exhaust vent outside.

Determine vent path:

n

Select route that will provide straightest and most direct

path outdoors.

n

Plan installation to use fewest number of elbows and turns.

n

When using elbows or making turns, allow as much room

as possible.

n

Bend vent gradually to avoid kinking.

n

Use as few 90° turns as possible.

Determine vent length and elbows needed for best

drying performance:

Use the following “Vent System Chart” to determine type of vent

material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified

in “Vent System Chart.”
Exhaust systems longer than those specified will:

n

Shorten life of dryer.

n

Reduce performance, resulting in longer drying times

and increased energy usage.

Install Vent System

1.

Install exhaust hood

12" min.

(305 mm)

12" min.

(305 mm)

2.

Connect vent to exhaust hood

Install exhaust hood and use caulking compound to seal

exterior wall opening around exhaust hood.

Vent must fit over the exhaust hood. Secure vent to exhaust

hood with 4" (102 mm) clamp. Run vent to dryer location using

straightest path possible. Avoid 90° turns. Use clamps to seal

all joints. Do not use duct tape, screws, or other fastening

devices that extend into interior of vent to secure vent,

because they can catch lint.

CONNECT VENT

1.

Connect vent to exhaust outlet

Using a 4" (102 mm) clamp, connect vent to exhaust outlet

in dryer. If connecting to existing vent, make sure vent is

clean. Dryer vent must fit over dryer exhaust outlet and inside

exhaust hood. Check that vent is secured to exhaust hood

with a 4" (102 mm) clamp.

Advertising