Starting up the powerstar, Checking for leaks and purging air, Adjusting the temperature dial – Bosch AE115 User Manual

Page 8: Adjusting the flow

Advertising
background image

Starting up the PowerStar

Checking for leaks and purging air

•

Verify all circuit breakers supplying power to the water heater are turned off.

•

Open all hot water taps supplied by the water heater and inspect all water connections for leaks.

•

With all hot water taps still open, inspect each tap to ensure all air in the lines has been purged out.

•

With the air purged and taps still flowing, turn on all circuit breakers supplying the water heater.

•

Close all hot water taps and proceed to the next section.

Adjusting the temperature dial

•

The temperature adjustment is made using the dial on the bottom edge of the unit. The adjustment
is between approximately 95°F and 135°F. Turning the dial clockwise increases the temperature
setting as indicated by the marking on the unit.

Adjusting the flow

•

Open fully both inlet and outlet shut-off valves at the heater, then :

•

Turn on fully the highest flowing hot water faucet (e.g., bathtub) served by the water heater.

•

Adjust the outlet shut-off valve until the water flow rate from the hot faucet corresponds to the value
given in Graph 1 below.

Graph 1

8








Outlet Temperature vs Maximum Flow Rate Setting

(based on incoming water temperature of 55°F)

AE125 Heater

AE115 Heater

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

5.00

95

100

105

110

115

120

125

130

135

Outlet Temperature (°F)

M

a

x

F

lo

w

R

a

te

(

U

S

g

a

l

/

m

in

)