S1-8: Carrier Control Method

The setting for switch S1-8 determines whether the carrier is

"constantly on" or "controlled by RTS". This setting allows for
operation in switched carrier, rnultipoint and/or hardware
handshaking applications.


S1-8 Setting
Off

Constantly On

On

Switched Carrier


3.3 CONFIGURATION SWITCH SET "S2"

The DIP switches on S2 set word length, extended signaling

rate, RTS/CTS delay and V.52 and V.54 diagnostic test.

Figure 4. Summary of DIP switch default settings for S2

S2-1 and S2-2: Word Length

Switches S2-1 and S2-2 are set in combination to determine the

word length for asynchronous data.

S2-

1 S2-2 Setting

Off

On

8

bits

On

On

9

bits

Off

Off

10

bits

On

Off

11

bits