Fig. 44 — Typical Wiring Schematic

LEGEND

AHA

— Adjustable Heat Anticipator

C

— Contactor, Compressor

CAP

— Capacitor

CC

— Cooling Compensator

COMP — Compressor Motor
D

— Diode

EC

— Enthalpy Control

ECON

— Economizer

EPS

— Emergency Power Supply

(Nine Volt Battery)

ER

— Economizer Relay

FPT

— Freeze Up Protection Thermostat

FU

— Fuse

GND

— Ground

HC

— Heater Contactor (Strip Heat)

HPS

— High Pressure Switch

IFC

— Indoor Fan Contactor

IFM

— Indoor Fan Motor

LPS

— Low Pressure Switch

LSM

— Limit Switch (Manual Reset)

MTR

— Motor

OAT

— Outdoor Air Thermostat

OFM

— Outdoor Fan Motor

PL

— Plug Assembly

QT

— Quadruple Terminal

R

— Relay

SAT

— Supply Air Thermostat

SEN

— Sensor

SW1

— Switch Fully Open

SW2

— Switch Fully Closed

SW3

— Switch Min. Vent Position

SW4

— Switch Max. Vent Position

TB

— Terminal Block

TC

— Thermostat-Cooling

TDR

— Time-Delay Relay

TH

— Thermostat-Heating

TRAN — Transformer

Field Splice

Marked Wire

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Splice

Splice (Marked)

Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or Optional Wiring
To indicate common potential
only. Not to represent wiring.

NOTES:
1. If any of the original wire furnished must be replaced, it must be

replaced with type 90 C wire or its equivalent.

2. Three-phase motors are protected under primary single phas-

ing conditions.

3. Thermostat:

HH07AT170, 172, 174 & P272-2783
Subbase:
HH93AZ176, 178 & P272-1882, 1883

4. Set heat anticipator at 1 amp.
5. Use copper conductors only.
6. Use copper, copper clad aluminum or aluminum conductors.