Caution, Aintenance and care – Bissell 89Q9 User Manual

Page 12

Advertising
background image

M

aintenance and care

Check your vacuum cleaner’s rotating floor

brush and drive belt regularly for debris, wear or

damage. Debris can wrap around the brush and

hamper its ability to effectively clean your carpet.
1.
Unplug cleaner from electrical outlet.
2. Remove detachable canister from vacuum

cleaner

3. Recline handle and turn vacuum cleaner

over so bottom side is up.

4. Remove the six screws as shown with a

Phillips head screwdriver. Lift the brush

cover off.

5. Lift the rotating floor brush to remove. Clean

strings, hair and other debris from the brush,

paying special attention to the brush ends.

6. Check air passageway for obstructions.

Remove any debris from this area.

7. Clean debris from the motor pulley and drive

belt areas.

8. Check drive belt carefully for wear, cuts or

stressed areas. If any damage is present,

discard old drive belt and replace.

9. Place one end of the new drive belt over

motor pulley and the other end over the

brush in the space between the bristles.

10. Pull the brush firmly to stretch the drive belt

and place ends of brush down into slots on

sides as shown. Turn brush several times by

hand to center the drive belt.

11. Reposition brush cover and screws. Tighten

screws securely.

Rotating brush and drive belt maintenance

Caution:

To reduce the risk of injury

from moving parts, turn

off vacuum cleaner and

disconnect Power Plug

from electrical outlet.

12

4.

10.

Air
Passageway

Motor
Pulley

Drive Belt

6.-8.

w w w . b i s s e l l . c o m

Advertising