NEW BUCK CAST COLLAR

Part # MA6CHIMCNB

C. Vertical wall exit using (6" Single Wall Pipe minimum 24 ga. blued

or black pipe and elbow pipe, and any listed 2100° UL 103 HT. TYPE

Chimney and Listed 2100° UL HT T-Box assembly).

With standard close clearance shield and pipe shield.

Model 261 minimum clearance to combustibles.

C

C

C

C

NOTE: All clearances are to combustibles with all low clearance shields and single wall pipe
with elbow, and minimum floor protector.NOTE: Floor protector must extend length of
horizontal flue pipe to wall. NOTE: Model 261 comes standard with low clearance shields.

Figure 7.

SINGLE WALL

CONNECTOR

ELBOW PIPE

IN
SIDE
WALL

CEILING

Maintain 18"Minimum Clearance

WALL
PASS-THROUGH
CONNECTOR

CENTER LINE

OF ELBOW
MARK PLUMB
LINE ON WALL

LISTED 2100° UL 103 HT TYPE

CHIMNEY REEFER TO

MANUFACTURERS

INSTALLATION INSTRUCTION

LISTED 2100° UL 103 HT

TYPE CHIMNEY T-BOX
ASSEMBLY REEFER TO

MANUFACTURES

INSTALLATION

INSTRUCTION

Figure 8.

BACK WALL

A

E

B

F

D

G

A

E

B

D

F

BACK WALL

SIDE WALL

PROTE

C

TO

R

G

A B C D E F G H


MODEL 261 13”

7" 13" 12"

8" 3" 16"

10"

H

NOTE:

13