Shovel attachment, Operating weight and ground pressure, Bottom dump buckets – Liebherr R 9350 User Manual

Page 21

Advertising
background image

R 9350

21

Shovel Attachment

with Shovel Boom 6,75 m/22’1”

Digging Envelope

Stick length

4,20 m/13’9”

Max. reach at ground level

13,75 m/45’1”

Max. dump height

11,20 m/36’8”

Max. crowd length

5,20 m/17’

Bucket opening width T

2,35 m/ 7’8”

Crowd force at ground level (ISO 6015)

995 kN/223,460 lbf

Max. crowd force (ISO 6015)

1.280 kN/287,755 lbf

Max. breakout force (ISO 6015)

1.000 kN/224,809 lbf

Operating Weight

and Ground Pressure

The operating weight includes the basic machine with shovel
attachment and a 18,00 m

3

/23.5 yd

3

bucket.

Pad width

mm/ft in 850/2’9”

Weight

kg/lb 310.000/683,400

Ground pressure *

kg/cm

2

/ psi 2,58/36.57

* according to ISO 16754

0

-10

10

20

30

30

40

50

ft

60

0

-2

-4

2

4

6

8

10

12

14

16

m

18

0

2

4

6

8

10

12

14

m

0 ft

10

20

30

40

50

T

Bottom Dump Buckets

For materials classe
according to VOB, Section C, DIN 18300

< 5

< 5

< 5

5 – 6

5 – 6

7 – 8

7 – 8

Typical operation
according to VOB, Section C, DIN 18300

GP

GP

GP

HD

HD

XHD

XHD

Capacity ISO 7546

m

3

15,30

17,00

20,50

17,00

18,00

15,30

16,50

yd

3

20.0

22.2

26.8

22.2

23.5

20.0

21.6

Suitable for material up to a specific weight of

t/m

3

2,2

2,0

1,6

1,9

1,8

1,9

1,7

lb/yd

3

3,710

3,373

2,698

3,204

3,035

3,204

2,867

Cutting width

mm 4.100

4.100

4.100

4.100

4.100

4.100

4.100

ft in 13’5”

13’5”

13’5”

13’5”

13’5”

13’5”

13’5”

Weight

kg 29.900

30.600

31.000

31.620

31.900

35.000

35.950

lb 65,918

67,461

68,343

69,710

70,327

77,162

79,256

Wear kit level

I

I

I

II

II

III

III

GP:

General purpose bucket with Liebherr Z140 teeth

HD:

Heavy-duty bucket with Liebherr Z140 teeth

XHD:

Heavy-duty rock bucket with Liebherr Z140 teeth

Level I: For non-abrasive materials, such as limestone, without flint inclusion, shot material or easily breakable rock,

i.e. deteriorated rock, soft limestone, shale, etc.

Level II: For preblasted heavy rock, or deteriorated, cracked material (classification 5 to 6, according to DIN 18300)
Level III: For highly-abrasive materials such as rock with a high silica content, sandstone etc.

Advertising
This manual is related to the following products: