Follow the instructions below to change the oven burner nozzle:
1) Remove the oven level (Fig. 9).
2) Loosen the screw V and pull out the burner from the support being careful not to damage the ignition plug and the
thermocouple (Fig. 10).
3) Unscrew the nozzle R (Fig. 10) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas
according to what is indicated in Table below
4) Re-install all the parts in revers sequence from 3 to 1
(Fig. 9)
(Fig. 10)
Follow the instructions below to change the broiler burner nozzle:
1) Loosen the screw and pull out the burner from the support being careful not to damage the ignition plug and the
thermocouple (Fig. 11).
2) Unscrew the nozzle R (Fig. 11) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas
according to what is indicated in Table below.
Models X244GGVX [MLS0GTU4X(2 or 5)A]
Adapting to different types of gas
Burner
Position
Injector
Gas
Pressure
Max Rate
Min Rate
By-pass
diam.
[mm.]
Type [i.w.c.]
[BTU/h]
[W] [BTU/h]
[W] diam.
[mm]
Auxiliary
Rear L
0,90
NG
4”
3400
996
900
264
Regulated
0,54
LP
(Propane)
11”
3400
996
900
264
0,29
Semi-Rapid
Front R
1,18
NG
4”
6100
1787
1500
439
Regulated
0,70
LP
(Propane)
11”
6100
1787
1500
439
0,36
Rapid
Rear R
1,55
NG
4”
10400
3047
2500
732
Regulated
0,92
LP
(Propane)
11”
10400
3047
2500
732
0,47
Front L Inner
0,80
NG
4”
2800
820
900
264
Regulated
Dual Burner
0,49
LP
(Propane)
11”
2800
820
900
264
0,29
Front L Outer
N°2 x 1,15
NG
4”
12000
3516
4500
1318
Regulated
N°2 x 0,70
LP (Propane)
11”
12000
3516
4500
1318
0,65
Oven
Oven 1,60 NG 4”
11000
3223
2400
703
Regulated
downside 0,95
LP
(Propane)
11”
11000
3223
2400 703 0,48
Broiler
Oven
1,50
NG
4”
10000
2930
Only Max
Only Max
No by-pass
upside
0,90
LP (Propane)
11”
10000
2930
Only Max
Only Max
No by-pass
CAUTION: save the orifices removed from the appliance for future use