Maintenance, Maintenance schedule, Pump preventative maintenance check list – Briggs & Stratton Pressure Washer User Manual

Page 17

Advertising
background image

17

Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse
conditions noted below.

1 Clean if clogged. Replace if perforated or torn.

2 Change oil after the first (5) operating hours and every 50 hours or yearly thereafter. Change oil sooner when operating under dirty or dusty conditions.

3 Replace more often under dirty or dusty conditions.

Maintenance Schedule - Fill in Dates as You Complete Regular Service

Maintenance Task

Service Dates

Service Dates

Before

Each Use

Every 25
Hours or

Yearly

Every 50
Hours or

Yearly

Every 100

Hours or

Yearly

Pressure Washer

Check / clean water inlet screen

X

1

Check high pressure hose

X

Check detergent siphoning hose / filter

X

Check spray gun and hose assembly
for leaks

X

Prepare pump for storage below 32°F

See Winter Storage

Engine

Check oil level

X

Clean debris

X

Change engine oil

X

2

Pre-Filter

X

Service air cleaner

X

3

Service spark plug

X

Service spark arrester

X

Air cooling system

X

3

Prepare for storage

If unit is to remain idle for longer than 30 days.

Follow the daily, hourly or calendar intervals, whichever occurs first.

* If other than CAT Pump Model 6107 oil is used, change cycle should be every 300 hours.

** Each system’s maintenance cycle will be exclusive. If system performance decreases, check immediately. If no wear at 1500 hours,

check again at 2000 hours and each 500 hours until wear is observed. Valves typically require changing every other seal change.
Duty cycle, temperature, quality of pumped liquid and inlet feed conditions all affect the life of pump wear parts and service cycle.

Remember to service the unloader at each seal servicing and check all system accessories and connections before resuming operation.
Contact your local service center if questions arise.

Pump Preventative Maintenance Check List

Maintenance Item:

Daily

50 hours

500 hours

1,500 hours

3,000 hours

Check Pump Oil Level/Quantity

X

Check for Oil Leaks

X

Check for Water Leaks

X

Break-in Oil Change

X

*Routine Oil Change

X

**Seal Change

X

Valve Change

X

Check Accessories

X

Change oil after the first (5) operating hours