Tilt circuit relief valves, Ircuit, Elief – Gradall 534D-6T Service Manual User Manual

Page 266: Alves 7.0

Advertising
background image

T

ILT

C

IRCUIT

R

ELIEF

V

ALVES

7.0

SET UP

1. Install a 10,000 PSI gauge, hose and adapter to the test port on

the outlet tube of the main implement pump. Make sure you can

see the gauge from the operator’s cab.

2. With the park brake engaged and the transmission in “Neutral”,

start the material handler.

CHECK

1. With the engine running at low idle (800-900 RPM) and holding

the Attachment Tilt Lever fully forward, observe the gauge.

2. The gauge should read 2800 ± 100 PSI for all Models except the

544C-10 and 544D-10 which should read 3000 ± 100 PSI.

3. Raise the forks (or other attachment) until the cylinder bottoms.

4. Observe the gauge while holding the Attachment Tilt Lever fully

backward.

Again, the gauge should read 2800 ± 100 PSI for all Models except

the 544C-10 and 544D-10 which should read 3000 ± 100 PSI.

ADJUST

1. Before attempting any adjustment, you must switch the engine

off! Also, make sure the park brake is still engaged.

2. If necessary, loosen the locknut and turn the adjusting screw

clockwise to increase pressure; counter-clockwise to reduce

pressure.

522, 524, 532C-6, 534C-6 and 534C-6T

MAIN IMPLEMENT TEST PORT

ALL OTHER MODELS

MAIN IMPLEMENT TEST PORT

TILT CIRCUIT RELIEF VALVE

NOTE!

The location of the main

implement test port varies by

machine vintage.

Advertising
This manual is related to the following products: