7 testing & final assembly, Re-sealing & filling the differential – ARB RD158 User Manual

Page 40

Advertising
background image

7 Testing & Final Assembly

38

c Turn the ignition to the ‘ON’ position (leaving the motor off). The

large illuminating symbol on the Air Locker switch cover should be
‘OFF’.

c Turn the compressor (or alternate air source) on to charge the air

supply up to its maximum pressure.

c Rotate one wheel by hand.
c The wheel should rotate freely and the opposite wheel should be

turning in the opposite direction without any resistance or
mechanical noise from within the differential.

c Turn the Air Locker switch to the ‘ON’ position. The illuminated

symbol on the switch cover should light up.

c Rotate the same wheel again.
c Both wheels should rotate together.
c Turn the switch off again.
c Rotate the same wheel.
c The wheels should again rotate in opposite directions.


7.3

Re-Sealing & Filling the Differential

NOTE : Consult the ARB Air Locker Operating & Service

Manual for recommendations on differential lubricant
specifications.


c Replace the differential cover using gasket sealant or a new

standard differential cover gasket for your make of vehicle.

c Refill the differential until level with the filler hole.
c Rotate the differential center 2 full turns.
c Check the oil level and add oil if necessary.
c Replace filler plug (apply thread sealant to filler plug before

inserting if it is a threaded type plug).

c Wipe differential housing clean of any oil or grease which may

collect dirt or other abrasive particles.

Advertising