3 installing the air locker – ARB RD121 User Manual

Page 16

Advertising
background image

3 Installing the Air Locker

14

c Assemble the shim pack onto the seal housing flange on the same

side as the seal housing tube’s solder joint.

c Assemble the seal housing into the bearing bore in the shallow half

of the clamshell (shims against the clamshell).

c Using a bearing press or arbor press, press the remaining bearing

cup into the bottom of the same bearing bore (until it stops against
the seal housing).

c Carefully assemble the shallow half of the clamshell over the top of

the Air Locker.

c Measure the preload gap that exists between the two halves of the

clamshell housing with a feeler gauge. (Refer to Fig.6.)

Figure 6.

NOTE :

The preload gap should be the same when measured
all the way around the housing. If this is not true, then
reposition the shallow clamshell half and re-measure.

c Subtract the amount measured at the preload gap from the

thickness of the shim pack placed onto the seal housing flange.

c Record the result as this is your true ‘end float’ amount.

Advertising