Complete installation and operating instructions are
provided separately with the SmartBox

™

.

■

U s e c u s to m e r s u p p l i e d w i r e n u t s a n d ot h e r
appropriate electrical terminals when interconnecting
the SmartBox

™

to the heater.

■

Refer to labels on wires for connections.

■

Ensure proper electrical wiring gauge for main power
supply from SmartBox

™

to heater.

■

Use 18 gauge electrical wiring for supply of DC volts
from SmartBox

™

to Smart Sense

™

variable rate gas

control on heater.

A.

115 Volt main power wiring from SmartBox

™

to

heaters.

Connect leads as shown in Fig.7 to heating Zones 1
and 2.

FIG. 7

B.

Wiring from SmartBox

™

to the heater’s Smart Sense

™

variable rate gas control valve

a. Connect Smart Sense™ gas control valve wiring for

Zones 1 and 2 at SmartBox

™

leads as shown in

Fig.8.

FIG. 8

b. Route the wiring from these leads through the gas

inlet hole at the heater’s case. See Fig.9.

c. Attach 1/4 in. insulated female terminals to these

wires and connect to either terminal on the valve.
See Fig. 9.

FIG. 9

d. See Fig.10 for typical connections. Each

SmartBox

™

zone can control two heaters.

FIG. 10

INTERCONNECTION FOR VARIABLE HEAT

ROUTE WIRING
THROUGH HOLE

CONNECT WIRING TO TERMINALS
( NOT POLARITY SENSITIVE)

12

ZONE 1 OR ZONE 2 WIRING FROM

SmartBox™

TO

Smart Sense™

VARIABLE RATE GAS CONTROL VALVE

VOL

TS T

O V

AL

VE

VA

LV

E

HEATER 1
GAS VALVE

HEATER 2
GAS VALVE

Advertising