Interconnection for variable heat – L.B. White Guardian with Smart Sense - Hot Surface (60K / 100K) User Manual

Page 12

Advertising
background image

Complete installation and operating instructions are
provided separately with the SmartBox

.

U s e c u s to m e r s u p p l i e d w i r e n u t s a n d ot h e r
appropriate electrical terminals when interconnecting
the SmartBox

to the heater.

Refer to labels on wires for connections.

Ensure proper electrical wiring gauge for main power
supply from SmartBox

to heater.

Use 18 gauge electrical wiring for supply of DC volts
from SmartBox

to Smart Sense

variable rate gas

control on heater.

A.

115 Volt main power wiring from SmartBox

to

heaters.

Connect leads as shown in Fig.7 to heating Zones 1
and 2.

FIG. 7

B.

Wiring from SmartBox

to the heater’s Smart Sense

variable rate gas control valve

a. Connect Smart Sense™ gas control valve wiring for

Zones 1 and 2 at SmartBox

leads as shown in

Fig.8.

FIG. 8

b. Route the wiring from these leads through the gas

inlet hole at the heater’s case. See Fig.9.

c. Attach 1/4 in. insulated female terminals to these

wires and connect to either terminal on the valve.
See Fig. 9.

FIG. 9

d. See Fig.10 for typical connections. Each

SmartBox

zone can control two heaters.

FIG. 10

INTERCONNECTION FOR VARIABLE HEAT

ROUTE WIRING
THROUGH HOLE

CONNECT WIRING TO TERMINALS
( NOT POLARITY SENSITIVE)

12

ZONE 1 OR ZONE 2 WIRING FROM

SmartBox™

TO

Smart Sense™

VARIABLE RATE GAS CONTROL VALVE

VOL

TS T

O V

AL

VE

VA

LV

E

HEATER 1
GAS VALVE

HEATER 2
GAS VALVE

Advertising