1.

Remove the screws securing the motor mounting
plate to the fan housing.

2.

Pull the fan and motor assembly from the housing.

3.

Loosen the square head set screw(s) on the fan
wheel with a wrench.

4.

Pull the fan wheel from the motor shaft. Use a wheel
puller if necessary.

5.

Remove the four (4) nuts securing the motor to the
mounting plate.

a. Fan wheel to motor mount plate spacing must

be adjusted to proper clearance before
tightening the fan wheel to the motor shaft.

b. Ensure set screw(s) of the fan are on the flats

of motor shaft when tightening.

FIG. 11

MOTOR AND FAN WHEEL ASSEMBLY

MOTOR MOUNT PLATE

FAN WHEEL

CLEARANCE

MOTOR

Service Instructions

1.

C l o s e t h e f u e l s u p p l y va l ve to t h e h e a te r a n d
disconnect the electrical supply before servicing
unless necessary for your service procedure.

2. Open appropriate case panel for access to heater

components.

3

Disconnect the appropriate electrical leads for the
component being replaced.

4. The high limit heat switch will open if it overheats. It

must be manually reset. If the high limit switch does
not reset, it can be tested by jumpering the switch out
of the electrical circuit.:

-- Reconnect the electrical supply and open fuel

supply valves.

-- If the heater lights, the component is defective and

must be replaced.

-- Do not operate the heater with the switch jumpered.

Replace the part immediately.

-- An alternate method for checking the components

is to perform a continuity check.

5. Do not jumper the air proving switch before the fan

motor is started by the ignition control. If jumpered,
the ignition control will not allow heater operation.
Test the air proving switch for continuity. If defective,
replace the switch

6. For reassembly, reverse the respective ser vice

procedure. Ensure gas connections are tightened
securely.

7. After servicing, start the heater to ensure proper

operation. Check for gas leaks with approved leak
detectors.

8. Clean the heater’s orifice with compressed air or a

soft, dry rag. Do not use files, drills, broaches, etc. to
clean the orifice. Doing so may enlarge the hole,
causing combustion or ignition problems. Replace the
orifice if it cannot be cleaned properly.

WARNING

Burn Hazard

Heater surfaces are hot for a period of time after the
heater has been shut down.

Allow the heater to cool before performing service,
maintenance, or cleaning.

Failure to follow this warning will result in burns
causing injury.

WARNING

Fire and Explosion Hazard

Do not disassemble or attempt to repair any heater
components or gas train components.

All component parts must be replaced if defects are
found.

Failure to follow this warning will result in fire or
explosions, causing property damage, injury, or death.

GENERAL

1/8 in.

Advertising