Igniter, Burner orifice – L.B. White 170 Tradesman Portable Forced Air User Manual

Page 15

Advertising
background image

MAINTENANCE

1.

Using a small wire brush, reach down the barrel of
the heater and brush the igniter electrode. Remove
any build up.

2.

Periodically check the gap. Gap should be 3/16 as
shown in Fig. 15.

FIG. 14

FIG. 15

REMOVAL

1.

Disconnect the ignitIon cable from the igniter. See
Fig.16.

FIG. 16

2.

Remove the igniter mounting screw and nut. See
Figs. 14 and 16.

1.

Loosen the compression nut at the burner orifice.
Remove the bowed retaining clip. See Fig. 17.

FIG. 17

2.

Reach down the barrel of the heater and pull the
orifice from the burner plate.

3.

Inspect the orifice and clean any plugged holes.
Replace it if necessary. The replacement orifice will
include retaining clips.

FIG. 18

IGNITER

15

BURNER ORIFICE

COMPRESSION NUT

BOWED CLIP

IGNITION CABLE

IGNITOR
ELECTRODE

3/16 in.

MOUNTING SCREW

MOUNTING
NUT

Advertising