Electrical connection and ladder diagrams – L.B. White 170 Tradesman Portable Forced Air User Manual

Page 24

Advertising
background image

24

Electrical Connection and Ladder Diagrams

WHITE

BLACK

CASE

GROUND

MOTOR

SOLENOID

GND GROUND

MV VALVE

SOLENOID

BURNER

GROUND

DIRECT

SENSE

IGNITER

GROUND

DIRECT SPARK

IGNITION CONTROL

THERMOSTAT

VALVE MV

ELECTRICAL LADDER DIAGRAM

IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THE HEATER MUST BE REPLACED, IT MUST BE

REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 302°F (150°C)

DIRECT SPARK

IGNITION CONTROL

NEUTRAL

POWER CORD

BLACK

OR RED

RED

BLACK

GREEN
GREEN

120 VAC L1

GROUND GND

NEUT

NEUT

GREEN

WHITE

L1 120V

NEUT
NEUT

L1

BLACK

150-28310

LIMIT

SWITCH

LIMIT

SWITCH

MOTOR

BURNER

GROUND

GREEN

BLACK

CASE

GROUND

WHITE

GREEN

ELECTRICAL CONNECTION DIAGRAM

WHITE

CAUTION - REFER TO THE HEATER'S ELECTRICAL CONNECTION DIAGRAM WHEN SERVICING

TO AVOID WIRING ERRORS & HEATER MALFUNCTION. CHECK FOR PROPER OPERATION AFTER SERVICING.

WHITE

WHITE

DIRECT SENSE

IGNITER

LIMIT

SWITCH

THERMOSTAT

LIMIT

SWITCH

WARNING: THIS HEATER MAY START AT ANY TIME

RED

RED

TRADESMAN 170 ULTRA

TRADESMAN 170

Advertising