Manual shut-off valve, hose and regulator assembly, Fig. 8 – L.B. White HW120 Plus Therma Grow User Manual

Page 13

Advertising
background image

13

MANUAL SHUT-OFF VALVE, HOSE

AND REGULATOR ASSEMBLY

REGULATOR

NIPPLE

VALVE, MANUAL
SHUT-OFF

GAS HOSE

ADAPTER

SEDIMENT TRAP

TO CONTROL

VALVE INLET

REGULATOR VENT

G

AS FLO

W

1.

Always use approved pipe thread compound suitable
for use with L.P. gas or natural gas on the threaded
connections.

2.

Assemble the components together according to the
figure. This view is to show general assembly of the
components only. The regulator must always be
mounted so its vent, regardless of location on the
regulator, is always pointed downward.

3.

Tighten all connections securely and check for gas
leaks.

FIG. 8

SECOND STAGE

REGULATOR

3. Operate both stages of heat.

GAS CONTROL VALVE

IGNITION CONTROL

IND

L1

HSI

HSIG

L2

W

PSI

FSI

GV

PSO

FSG

C

YELLOW

GREEN

GROUND

BLACK

WHITE

FIRST STAGE HEAT CONTACT

SECOND STAGE HEAT CONTACT

YELLOW

BROWN

BROWN

BROWN

RED

LO

GROUND

HI

C

GREEN

HIGH LIMIT SWITCH

TRANSFORMER

24V

120V

Advertising