Heater specifications, Model – L.B. White HW120 Plus Therma Grow User Manual

Page 4

Advertising
background image

SPECIFICATIONS

HW120

Propane

Natural

Gas

Gas

Maximum Input (BTUH)

120,000

Minimum Input (BTUH)

65,000

300 CFM

120 sq. in.

64 sq. in.

13.5

11.0

11.0

7.0

5.0

3.1

1.4

0.8

5.56 lbs.

120 cu. ft.

3.01 lbs.

65 cu. ft.

Ball Bearing

1/3 H.P.

1,100 RPM

115/60/1

11.8

4.5

30 3/4 x 21 x 28 1/4

TOP

1 ft.

SIDES

1 ft.

BACK

1 ft.

BLOWER
OUTLET

GAS

Propane Gas Supply — 6 ft. (1.83 m)

SUPPLY

Natural Gas Supply — N/A

(1) Air inlets and exhaust outlets must be electromechanically operated and electrically interlocked with the heater

to prevent heater operation if air inlet and exhaust outlet do not open when heating is required.

Model

Indoor Mounting Air
Exchange Requirements

(1)

Burner Manifold
Pressure (In. W.C.)

Electrical Supply
(Volts/Hz/Phase)

Amp Draw

Dimensions (Inches)
L x W x H

Minimum Safe
Distances From
Nearest
Combustible
Materials

STARTING

CONTINUOUS
OPERATION

Motor Characteristics

Fuel Consumption Per
Hour

Inlet Gas Supply
Pressure Acceptable at
the Inlet of the Heater
for Purpose of Input
Adjustment (In. W.C.)

MAX.

MIN.

MAX.

MIN.

6 ft. (1.83 m)

4

Heater Specifications

Outdoor Mounting Air
Exchange Requirements

(1)

EXHAUST FAN

SHUTTERED AIR INLET

SHUTTERED
EXHAUST OUTLET

MAX.

MIN.