Service instructions, Gas pressure checks – L.B. White 100 Workman - Standard LP User Manual

Page 11

Advertising
background image

11

Service Instructions

PLUG

CONNECTOR

HIGH PRESSURE GAUGE

GAS PRESSURE CHECKS

Fig. 3

ATTENTION

This procedure is to be done once a year prior to the

heating season, anytime the heater is moved from one

job location to the next, or after servicing the heater.

MATERIALS REQUIRED

(To be secured through local purchase)

Quantity

Description

1

High Pressure Gas Gauge capable of

reading up to 15 PSIG

A. PREPARATION

1. Close fuel supply valve at propane gas supply

container.

2. Allow heater to burn off gas remaining in it’s gas

supply line..

3. Close manual main burner valve on heater.

B. GAUGE INSTALLATION

1. Using an allen wrench, remove the hex plug as shown

in Fig. 3.

2. Attach the pressure gauge to this point. See Fig.3.

3. Open fuel supply valves to heater.

C. READING PRESSURES

1. Start the heater. With the heater operating, the

pressure gauge should read the pressure specified

on the dataplate or in the specification section of this

owner’s manual.

2. Does the pressure reading agree with that given on

the dataplate? If so, no fur ther checking or

adjustment is required. Proceed to section D.

3. If the pressures does not agree with that specified on

the dataplate, then check the following:

-- Improper regulator for heater.

-- Regulator out of adjustment.

(Replace if necessary).

-- Blockage in gas hose.

-- Insufficient size or quantity of propane gas supply

containers.

D. COMPLETION

1. Once the proper pressure has been confirmed, close

fuel supply valves.

2. Allow heater to burn off fuel remaining in gas supply

line.

3. Remove gauge, hose adapter, nipple and tee.

4. Install hex plug. Tighten securely..

5. Tighten all connection securely and check for gas

leaks.

WARNING

Do not disassemble the pilot safety control valve.

Do not attempt to replace any components of the pilot

safety control valve.

The pilot safety control must be replaced if any

physical damage occurs to it.

Failure to follow this warning will result in fire or

explosions, leading to injury or death, and building

damage.

Advertising