Start-up instructions, Shut-down instructions – L.B. White 100 Workman - Standard LP User Manual

Page 9

Advertising
background image

9

Start-Up Instructions

1. Slowly open the fuel gas supply valve.

2. Fully depress the button on the pilot safety control

valve while pushing the igniter button. The pilot will

light. See Fig. 2.

Fig. 2

ATTENTION

On new installations it may take a short time for gas to

purge out any air in the pilot line before the pilot stays lit.

3. Keep the pilot button depressed for about 30

seconds to allow the thermocouple to warmup so the

pilot stays lit after the pilot button is released.

4. Fully open the manual main burner valve located

between pilot safety control and burner, the main

burner will light.

WARNING

Burn H

Hazard

Close the manual main burner valve before lighting the

pilot.

Failure to do so will result in the main burner igniting

when the pilot is being lit.

Serious injury or death due to burns may occur.

PILOT GAS VALVE

PILOT BUTTON

PIEZO IGNITER

PIEZO
IGNITER
BUTTON

GAS INLET ELBOW

MAIN
BURNER
VALVE

THERMOCOUPLE
LEAD

Shut-Down Instructions

1. Close all fuel gas supply valves.

2. Allow the heater to burn off any fuel gas remaining on

the gas supply line.

3. Close the manual main burner valve on the heater.

4. Disconnect the heater from its gas supply.