Installing dust filter, Important, Fig. 6 – L.B. White I-40 Infraconic Ignition User Manual

Page 10

Advertising
background image

1100

The zone control panel is a remote mounted control system

allowing the operation of a specific amount of heaters within

a certain zone of the building.

These panels will control the following quantity of heaters

depending on fuel type.

The zone control panel must be mounted to a flat, stable

wall inside the building. Use lag screws provided. For the

modulating zone panels, care must be taken to ensure that

the thermostatic control module is not exposed to outside

air temperatures. Exposure of the thermostatic control

module to outside air temperatures (Example: when

sidewall curtains are open) may cause the heater to provide

unwanted heat.

There are a number of optional configuration zone control

panels available. These include high and medium capacity,

modulating thermostatically controlled for stand alone, non-

electrical operation, as well as solenoid controlled for

incorporation into the building’s environmental control

system. Consult your local L. B. White dealer or distributor

or call the L. B. White Co. for recommendations on the best

configuration of zone panels for your specific application.
The zone control panel must have an adjustable high

pressure regulator installed upstream of the inlet of the

zone control panel. This regulator may be purchased from

the L. B. White Co. as an optional accessory. For L.P. gas,

the regulator must be capable of handling a maximum inlet

pressure of 10 psi, while supplying an outlet pressure of 5

psi nominal. This pressure is supplied to the zone control or

individual controlled heater. For natural gas, a regulator

must be installed to supply an outlet pressure of 5 psi

nominal.

ZONE CONTROL PANEL

COMPONENT FUNCTION AND INSTALLATION

Modulating System

Medium

High

Model and

Capacity

Capacity

Heat Output

Fuel

Panel

Panel

Quantity

Quantity

I

40

L. P. Gas

7

(40,000 BTUH)

Natural Gas

4

20

IMPORTANT

This filter kit is designed to provide additional dust filtration

capability and capacity for Infraconic heaters when

installed in severely dusty environments.

1. Attach filter adapter to injector body. The injector

body tabs fit into the slots on the adapter. Rotate the

adapter to lock it onto the injector body.

2. Position the filter onto the adapter. Ensure all

adapter holes are covered by the filter.

3. Securely attach the filter to the adapter using the

beaded cable tie.

4. Ensure filter does not sag or touch heater’s canopy.

INSTALLING DUST FILTER

(Optional accessory on some heater models)

FIG. 6

INJECTOR BODY TABS

FILTER ADAPTER

PART #23931

BEADED CABLE TIE

DUST FILTER

PART #23953

INJECTOR

BODY

TABS

FILTER SLEEVE

PART #20421

BEADED

CABLE TIE

DUST FILTER

PART #81649

FILTER SLEEVE