Fast & Fluid Giotto Column User Manual

Page 21

Advertising
background image

Fast & Fluid Management

A Unit of IDEX Corporation

________________________________________________________________________________

________________________________________________________________________________

20

1154915C-it,en,fr.doc - 15/10/2003

The electrical plug has to be connected to a mains socket which is correctly earthed.

During any maintenance operation or by any intervention on the machine , the electrical plug must

absolutely be extracted from the socket.

Before starting the machine with the timer, verify that all covers of the containers have been correctly

blocked.(DIAGRAM 6)

The sound emission relative to the work station is less than 70 dB.

14.- WHAT TO DO IF. . .

-

The colourant comes out in spurts of colourant during the dosing action.

>> Check of the quantity of colourant inside the canister.

Operate on the pump, without opening the valve , several times so the air can go

back into the canister.

-

Colourants appears on the piston shaft or at the bottom of gauge.

>> This problem indicates that the seals are worn. Replace referring to

"REPLACEMENT OF PISTON SEAL".

- Difficult rising action for piston

>> Each canister is equipped with three different diameter nozzles. Increase the size for this

colourant. If this action doesn' t solve the problem, clean the canister, the pump and replenish

with fresh colourant.

Advertising