© Fast & FLuid Management, TmHC manual

Service

When (re)placing the front panel on the door’s framework, make sure
the door is closed and locked. This guarantees the door’s relatively
flexible framework is ‘stiffened’ in the correct shape and position.

Pump & box holder module replacement

>

>

Choose: Maintenance >
Go To > Position and enter
desired value +6 to have the
defect module position to the
left-hand side of the TMHC.

Remove the left-hand side
panel by unscrewing its four
fasteners.

Remove screws on either side
of the pump.

>

>

The complete module can
now be shifted outward and
removed.

When placing the new
module, place ensure its rear
‘hook’ is correctly inserted in
its slot on the table. If not,
the back of the module will
not align.

Press the disc fully down and
the valve handle up.

In the unlikely event of a box holder or pump being damaged, we
suggest to replace the whole module.