Frequencies – BNC 745-20C-T User Manual
Page 22

User's Manual - MOD745-20
October 2014
Page 22 / 30
6.2.7. FREQUENCIES
Syntax:
FREQ F<n>,<F>
FREQ? F<n>
Form:
Set & Query
Description:
Query frequency of internal Frequency <n> or set frequency of internal
Frequency <n>
Parameter:
<n>: 1, 2 or 3 (Frequency 1, Frequency 2 or Frequency 3)
<F>: Frequency (in Hertz)
RST value:
Last value set
Range:
0.1 to 1 000 Hz (in 1, 2, 5 sequence)
Example:
Set internal Frequency 3 to 0.5 Hz: FREQ F3,0.5
Query frequency of internal Frequency 3: FREQ? F3
(Answer: :FREQ F3,0.5)
6.2.8. RUN
Syntax:
RUN
Form:
Set
Description:
Run a unique single shot sequence (
Same function as the “TRIG”
button on the touch screen
or “Trigger” light/button on web page)
Parameter:
none
RST value:
-
Example:
Run a single shot sequence: RUN