Warning, Confirmation, Fuel press – Defi Link Meter User Manual

Page 32

Advertising
background image

85

FUEL PRESS.

Use a commercial three-way joint and hose unions

●Be sure the sensor wire is not twisted when installing the sensor. The sensor wire will be cut.
●The sensor must be installed on the feed(high pressure)pipe side between the

fuel tank and the fuel pressure regulator.

*It is not possible to obtain accurate fuel pressure from the return(low pressure)

side at the rear of the fuel pressure regulator.

●The thread size of hose unions and the three-way joint need to be 1/8PT.

If the thread size of the three-way joint is 1/8NPT, you will need the 1/8NPT / PT

conversion socket(optional part). If it is neither 1/8PT nor 1/8NPT, you will need
to purchase a conversion adapter available from hardware stores.

●Tighten the sensor into the sensor attachment and then connect it to the sensor wire.

Fuel pressure regulator

Three-way joint
(commercially available)

*Cut the fuel feed pipe and

install hose unions.

Fuel return pipe

(low pressure)

Hose union
(commercially available)

Fuel feed pipe(high pressure)

Sensor

To sensor wire

↑

Wind Teflon tape.

Fix tightly with
clamps.

(commercially

available)

Thread size 1/8PT

Be sure not to
twist.

WARNING

●To avoid fuel leaks during installation of the sensors, use Teflon tape. Attach hose

connection and fuel feed tubing with a T-Bolt clamp. Inspect pipes and hose
connections for leaks before driving.

●Before cutting the fuel feed pipe, be certain to remove the gas cap to relieve any

pressure built up in the fuel tank.

●When cutting the fuel feed pipe, be certain to discharge static electricity.

Otherwise, there is a possibility of the ignition in gasoline.

●To avoid the damage of sensor wire, please fix the waterproof connector on the

vehicle body.