Installing the raptor™ fuel pump wiring harness, Figure 12, The raptor™ wiring harness – PureFlow AirDog RP-150 - 6.0L Ford 2003-2007 User Manual

Page 12: Figure 13, Figure 14, Figure 15

Advertising
background image

12

Raptor™ 100 & 150

2003 - 2007 Ford PowerStroke

Section 6 Electrical Harness













Figure 12

Installing the Raptor™ Fuel Pump wiring harness

.


Ground Wire

Hot Lead

The Raptor™ wiring harness.

Water Proof Fuse


Raptor Pump Lead

Figure 13

6-1.

To connect the Power Supply Lead to the Raptor™. Insert the 2 pin Deutsch connector on

the end of the wiring harness into the corresponding connector on the Raptor™.


Figure 14


6-2.

Route the Raptor™ 'activation lead', to the fuse panel on the dash to the left of the
steering column. Attach spade connector into a spare fuse holder on the panel that is
“hot” when the starter key is turned to the on position. Or connect it to the High Pressure
Pump Lead.



Figure 15



6-3.

Connect the Black (-) wire to an adequate ground.

BE SURE TO PROPERLY SECURE THE WIRING HARNESS TO THE VEHICLE.