INSTALLING THE SLIM LINE® INSTRUMENT SERIES

PAGE 5 OF 14

REV

B

from engine

MP Sensor

T-fitting

connector

MP gage

11) Induction Air (IAT), Compressor Discharge Temperature Probe Installation

The Induction Air Temperature probe, (IAT), is installed just after the inter-cooler and the Compressor
Discharge Temperature (CDT) just before the inter-cooler. The probe is the same as an EGT probe and installed
similarly to an EGT probe. A large clamp is supplied to fit around the air port leaving the inter-cooler.
Alternately a 1/8 NPT fitting is available.

12) Carburetor (CRB) Probe Installation

Locate the access hole in the carburetor near the butterfly valve. Remove the screw plug and screw the CRB
probe into the carburetor throat.

13) Manifold Pressure (MP) Sensor

Installation

Install a T-fitting (not supplied) in the aircraft’s MP
gauge line in the cockpit near the MP gauge. Install
the MP sensor on the T-fitting. Later, you will
connect the MP sensor to the wiring using the 4-pin
connector supplied.

14) Oil Pressure, Fuel Pressure, Boom Pressure Sensor Installation

Mount the two ring-spade lugs to the two terminals on the sensor using the hardware supplied. Mount the
pressure sensor to the pressure line using a 6 inch flexible hose and fittings (not supplied) as depicted in the
drawing below. Use tie-wraps to mount the pressure sensor an engine mount structure. Do not mount the sensor
directly to the engine. Connect the other end of the hose to the existing pressure line, with a T-fitting if
necessary. Later, you will connect the pressure sensor to the two pressure sensor wires.

pressure

sensor

flexible tube 6 inch (AEROQUIP 303)

AN-910-1D

1/8 NPT coupling

AN-816-4D
1/8 NPT to flared

MIL-H-8794 hose
MS-24587 fitting (AEROQUIP 491, 2 req'd)

to engine

fitting

DO NOT MOUNT SENSOR DIRECTLY TO ENGINE

15) VOLT/AMP Shunt Installation

Install the current shunt in the electrical system.
Charge/Discharge configuration. The shunt can be installed between the master contactor and the main bus in
which case it will be in the ammeter configuration showing battery charge and discharge. Be sure that the
positive side of the shunt is connected to the main bus in the ammeter configuration. The alarm will be triggered
by a discharge condition.