FS-450 Fuel Scan

Parameter Indexing Sequence

Fuel flow rate is always shown on the top display.

Fuel Flow Rate Single

I3.5

GPH (or LPH, or PPH)

Fuel Flow Rate Twin

14.4

13.7

GPH (or LPH, or PPH)

The lower display shows the following parameters in this
sequence.

Parameter

Description

Example

Comments

USD—Total Fuel Used

38.2

Since last refueling or trip total.

REM—Fuel Remaining

37.2

In gallons, liters or pounds

H.M.—Time to Empty

02.45

Hours . Minutes Remaining at
current fuel burn

REQ—Fuel required to next
GPS WPT or Destination

25.8

Present with GPS interface
Valid signal and way point

RES—Fuel Reserve at next
GPS WPT or Destination

1
1.3

Present with GPS interface
Valid signal and way point

MPG (both REQ & RES
lights)—
Nautical Miles per
Gal

13.0

Present with GPS interface and
valid signal or MPL, MPP

Note that liter and pound parameters are displayed as whole
numbers without the decimal point.

Section 5 - Personalizing

Pilot Programming

Setting Tank SIZE for the first time. Hold the STEP button in and
power up to see and set size.

You can program the Automatic Indexing rate (1 to 9 second wait
periods or 0 for no Automatic Indexing), the K-factor, and whether
to accumulate fuel used or reset at each refueling.

To start the Pilot Programming Procedure, simultaneously hold the
STEP and AUTO buttons for five seconds. You will see the words

for two seconds and then the sequence