J.p.instruments, Fuel flow installation manual, Specifications and limitations – J.P. Instruments EDM 760 Fuel Flow Installation Manual User Manual

Page 6

Advertising
background image

J.P.Instruments

Fuel Flow Installation Manual

Report # 760

for EDM-760 temperature indicating system with Fuel Flow Option

Appendix - A

Page Page 6 of 14 Rev NC :
Date 07/20/99

7…

Specifications and Limitations

Model:
EDM- 760(), with Fuel Flow option

Case Dimensions:
2.5" x 2.5" x 7.5" depth, 3.125" Bezel.

Weight:
Unit Only:

16 oz

Flow Transducer:

3 oz

Environmental;
Passed TSO C43c and DO-178a (software level 3)

Power Requirements:
10 to 35 Volts, 2 Amp.

Low Fuel Warning Display
The display message will blink anytime the programmed Low Fuel Reminder, Low Fuel Warning or the Time
to Empty Limit are violated.

External Warning Control Line:
Grounds external light when any EDM-760 warning display is on or blinking. Current should be limited to
2/10 amp.

Accuracy:
Flow:

2% or better in accordance with TSO C44a.

Resolution
Fuel Flow:

0.1 Gal. or 1 Lb. or .1 Ltr.

Fuel Remaining:

0.1 Gal. or 1 Lb. or . 1 Ltr.

Fuel Used:

0.1 Gal. or 1 Lb. or .1 Ltr.

Time to Empty:

10 minute

Max Displayed Range (Unit Only):

Fuel Flow:

199.9 Gals. or 162.0 or Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.

Fuel Remaining:

999 Gals. or 811 or Gals. or 1999 Lbs. or 1999 Ltrs.

Fuel Used:

999 Gals. or 811 or Gals. or 1999 Lbs. or 1999 Ltrs.

Time to Empty:

19 hours 59 minutes