Engineering
Standards
Name
Identifier
OEM Installation and Calibration
Engineering Standard Number
C1-105593
Four Output Tank Level
ISO 9001 CERTIFIED
E:\
MANUALS
\
DIGITAL
\
TANKLEVEL
\N
EW
T
ANK
L
EVEL
_ESN.
P
65_05062001
Connector information:
Connector
Terminal
Lock
Deutsch DTM06-12SA
0462-201-20141(18-24 Ga.)
WM-12S
1062-20-0122 (10-16 Ga.)
1
1/4 indication output
7
NC
2
NC
8
Transducer +5 VDC output
3
NC
9
Full indication output
4
3/4 indication output
10
1/2 indication output
5
Transducer Signal input
11
Transducer Ground output
6
NC
12
Ground
#10 Ring terminal
Output Driver Power
LED Status
Red
PWR System Power and Ground OK
Amber
BUS Driver Power OK
Green
COM Flashes 8X on power up and then steady
The module is waterproof and can be mounted in almost any location. Avoid areas of Ex-