System configuration, Figure1 – Class1 Electrical System Manager User Manual
Page 4

4
System Configuration
The Electrical System Manager is configured by the use of five jumpers
labeled J1 through J5.
J1 and J5 control battery monitoring (MAIN or MAIN and ISOLATED.)
J2 controls the load reset method (MANUAL or AUTOMATIC.)
J3 controls Load Sequencing (OFF or ON.)
J4 controls when Terminal bar #15 is active (Low Voltage or High Voltage.)
The System Manager cover must be removed to change its operating mode.
J1 through J4 are located at the lower right edge of the circuit board, J5 is
located next to TB #10.