Class1 Vernier Throttle for CAT User Manual
Page 7

7
DOC 101057C_c:\manuals\throttles\cats\catthrot.p65
3176/3406
Class 1
CAT Interface
C2-B
Throttle Signal
C1-A
12 VDC
12 VDC
Relay 2
87a
87
85
86
30
PTO
FAST
IDLE
OEM
Interlocks
Fast Idle
Switch
HIGH IDLE POT
Relay 1
87a
87
85
86
30
Relay 3
87a
87
85
86
30
VERNIER THROTTLE
C4
5 VDC
SIGNAL
GROUND
C2-A
C2-C
C2-B
HOOKED IN PARALLEL TO HIGH IDLE POT.
CONNECT TO VERNIER THROTTLE INPUT AT RELAY 1
HOOKED IN PARALLEL TO HIGH IDLE POT.
VERNIER THROTTLE
HIGH IDLE POT.
FROM C2-C
CONNECT TO HIGH IDLE POT INPUT AT RELAY 1
FROM C2-A
RELAY 3 DISABLES HIGH IDLE WHEN OK TO PUMP/PTO ENGAGED SIGNAL IS PRESENT
RELAY 2 SELECTS THE SOURCE OF THE INTERLOCK (HIGH IDLE OR PTO)
RELAY ONE SELECTS WHICH THROTTLE SIGNAL (HIGH IDLE OR VERNIER) IS DELIVERED TO THE INTERFACE MODULE
manuals\throttles\cat\catvthi.ai..110298
Wiring the Class1 Vernier Throttle with a remote high idle option