Class1 ITL Tank Level Driver Module 107451 User Manual
Page 7

Intelli-Tank Manual (106759) 050304
– 7 –
Class 1
Power and Ground
It is imperative that the driver module and the Master tank level have a common ground.
Stud
Vehicle power (12/24VDC)
Pin 12
Ground
High Current Outputs (7.5A)
Pin 1
Output 1
(1/4)
Pin 11
Output 2
(1/2)
Pin 9
Output 3
(3/4)
Pin 7
Output 4
(FULL)
Auto-Fill components
Pin 2
Auto-Fill status light output (+V)
Pin 4
Fill output (+V)
Pin 8
Auto-Fill select input (ground = auto-fill ON)
1-Wire Data Line
Pin 10
Data transfer line
Alarm functions
Pin 3
Alarm output (+V)
Pin 5
Alarm silence (ground = silence active)
Dim lights
Pin 6
Dim lights input (ground = dim active)
Display Panel (106878) wiring with the ITL Remote Driver Module
Display Panel
Remote Driver Module Connector