Maintenance, Maintenance schedule, Fluid levels – MBW MM121 User Manual
Page 9: Engine maintenance, Engine speed, Cleaning, Aintenance
- 6 -
M
AINTENANCE
WARNING
Always exercise the stopping procedure before
servicing or lubricating the unit.
After servicing the unit, replace and fasten all
guards, shields, and covers to their original
positions before resuming operation.
CAUTION
Always verify fluid levels and check for leaks after
changing fluids.
Do not drain oil onto ground, into open streams,
or down sewage drains.
Maintenance Schedule
1.
Check all hardware after the first 5 hours of use, then follow the maintenance schedule.
2.
Retorque lug nuts, front leg, and axle hardware after the first 25 miles travelled, the follow the maintenance schedule.
3.
Change filter after the first 10 hours of use, then follow the maintenance schedule.
Fluid Levels
Engine Maintenance
Refer to the engine owner’s manual for maintenance
intervals and procedures.
Engine Speed
Engine speed is factory set according to the speed listed in
the Specifications section of this manual. Refer to the
engine owner’s manual for procedure on setting operating
speed if necessary.
Cleaning
Always clean the mixer thoroughly after each day’s
operation. Dried mortar inside the drum can damage the
paddles and shorten the life of the mixer. Additionally, future
batches of mortar can be contaminated if the drum is not
clean.
CAUTION
Do not pound on the drum to clean dried mortar;
this will cause damage to the drum.
SYSTEM
MAINTENANCE
EACH USE
EVERY 40
HOURS
EVERY 100
HOURS
YEARLY
Axle
Check tire pressure
X
Grease wheel bearings
X
Drum
Grease trunnions & pillow blocks
X
Engine
Refer to engine operator/owner manual
X
Hardware
Check and tighten as needed
1,2
X
Hydraulics
Check oil level
X
Check for oil leaks
X
Change oil
X
Clean suction strainer
X
Change filter
3
X
SYSTEM
FLUID VOLUME
RECOMMENDED OIL
Model
MM91
MM121
Chevron Rykon AW ISO 32 Hydraulic Oil
Hydraulics
13.5 gallons
15 gallons
Engine
Refer to engine operator/owner manual