14 troubleshooting – Lukas LS530EN User Manual

Page 14

Advertising
background image

14

14 Troubleshooting

If the defects cannot be repaired, contact an authorised LUKAS dealer or the LUKAS
service department.
The address: LUKAS Hydraulik GmbH, Weinstraße 39, D-91058 Erlangen, Pf 2560,
D-91013 Erlangen, service phone 09131/698 348; fax 09131/698 353

Trouble

Check

Cause

Remedy

Hoses cannot be

Pressurized

Relieve pump

coupled

pressure

On actuating blades Hoses correctly

Air in the hydraulic

Thoroughly vent pump

move slowly or by

connected,

system

unit: see 9.1.1

jerks

power pack
operating

No pressure build-up

Not enough oil in

Refill oil and vent the

hand resp. motor

system (see

pump. Vent pump

operating instruction

after changing oil.

9.1.1)

Star grip doesn't

Return spring is

Ask authorized dealer

return to middle

damaged or return

or LUKAS themselves

position when

mechanism is dirty

for repair

released

Oil leakage out of

Untightness,

Replace hoses

hoses or hose fittings

eventually damages

Surface of hydraulic

Contact wirh

Change hoses

hoses is dissolved

agressive fluids

Blades spread up at

Torque of the center

For retightening, see

tips to a gap of more

bolt nut is unsufficient 13.2.1

than
3 mm (LS511EN) /
5 mm (LS501EN,
LS530EN) even if not
fully loaded
Leakages on the

Defective piston rod

Replacement of seals

piston rod

seal

by authorized dealer
or LUKAS themselves