8connection of the tool – Lukas LS530EN User Manual

Page 8

Advertising
background image

8

7.2 Connection diagram

For your better understanding the hydraulic diagram is
showing in simplified manner the tool's hydrauliccylinder (A)
with control valve (B).

7.3 Control of movements in operation

The arm movement is controlled by the firmly mounted star grip control valve (see
cover page item 1).

7.4 Hydraulic oil supply

LUKAS motor/engine pump or hand pump is used for operating the devices.
If the power pack comes from a manufacturer other than LUKAS, it must be ensured
that it fulfils the LUKAS specifications, as otherwise dangers may occur for which
LUKAS cannot be held liable. Especially it has to be made sure that the permissible
working pressure of 63 MPa (630 bar) is not exceeded.

7.5 Hoses

The connection between motor pump and cutter unit is normally effected with LUKAS
hoses. If pipes are to be used, please contact LUKAS.

8

Connection of the tool

8.1 Hydraulic

Two short hoses (each 0.5 m long) are fitted to the tool; they are connected with the motor
pump via a hose pair (5 m / 10 m / 20 m, as is necessary). All hoses are colour marked
and have quick-connect couplings so that they can be connected without the risk of mix-up:

HP = High pressure ——> red

R = return ——> blue

8.2 Connection of the plug-in coupling counterparts for HP and R hoses

The device is connected to the hydraulic pump with the plug-in coupling counterparts
(plug and socket), there being no risk of mix-up.

Before coupling, remove the dust protection covers and unlock the connect socket with
adjusting ring by turning it. Withdraw the sleeve and connect plug and socket while
holding the sleeve in this position. Release the sleeve and set the showglass to „red“
with the adjusting ring. Now the parts are connected and locked. Decoupling is done
in the reverse order.