NOTE:

With the LUKAS hand pump, a little idle stroke may occur when the unit is first

used in the high pressure range.

However, this idle stroke independently stops after a device is operated

2-3 times.

7.1 Locking the pump

ATTENTION!

The hand pump should be as close to horizontal as possible, because otherwise

the usable amount changes!

The oil fill plug must always be unscrewed one turn before starting operation of

the hand pump! This enables the aeration and bleeding of the hydraulic tank.

After the work is completed but before transport, the oil fill plug should be

retightened!

Commissioning

7.

7.2 Bleeding the pump

1. Open the discharge valve.

2. Open the oil fill screw plug on the tank container and check the oil fill level. The oil fill

level should come up to approximately 1-2 cm below the top edge of the oil reservoir.

3. In this state, work the pump handle several times.

Hand wheel

Unlock:

Lock:

ATTENTION!

Always push the locking lever fully to the end position, both when locking and

when unlocking!

When locking the hand pump, the pump lever must always be in the home

position (end position against the pump body)!