Lukas ZPH 3/4 User Manual
Page 19

19
Removing the ZPH1/HM1 1l tank:
3. Remove the nut (item E) and sealing ring situated under it (item F).
4. Remove the tank, the seals (item G), the cover (item R) and the filter (item H). On the
rescue hand pumps, the intake pipe (item J), the threaded rod (item K), the washer (item
L), the O-ring (item M), the serrated washers (items N, O and P) and the bracket (item Q)
must also be removed.
6. The assembly is done in reverse order. Replace all damaged parts with new ones. The
tightening torque of the nuts is 40 Nm.
Removing the ZPH1/HM1 5l and 12l tanks:
3. Remove the screws (item R) and the lock washers under them (item S).
4. Remove the tank, the O-rings (items T and U), the serrated washer (item V) and the filter
(item W).
6. The assembly is done in reverse order. Replace all damaged parts with new ones. The
tightening torque for the screws is 10 Nm.
S
R
W V T U
F
E
N
Q
N
G
O
L
M
H P
G
R
K
Tank
J
Pump head