8.3

Determine proper port location, and position pump assembly accordingly.

8.4 Install 4 bolts and torque to 20 in-lbs.

8.5 Test pump to applicable specifications for the pump/motor combination.


9

Storage

9.1

Prepare the pump for storage by installing plugs into the inlet and outlet ports.
Note: Tape can be used in lieu of plugs for sealing ports.

Remove as much fluid as possible from the pump prior to sealing ports.


9.2

Store the pump in any position in an ambient temperature-humidity environment.

Note: If water is left in the pump, damage may occur if the
temperature drops below freezing.