Eagledrive lead wire assignments – Micropump EagleDrive ELE User Manual
Page 13
Advertising

13
DOC No: 8540 REV D
MODEL MS
1
2
3
4
5
7
8
9
6
1
2
3
4
5
7
8
9
6
MODEL EL
Lead
Function
Color
1
Power In
Red
+12 to +36 VDC, Class 2 (SELV),
Reverse-polarity protected
2
Common
Black
Isolated from motor housing
3
Control Signal In
Yellow
0-5 VDC
4
Tachometer Out
Green
5 V square wave-2 pulses per
revolution
5
FWD/REV
Orange
Forward (float and insulate), Reverse
(ground)
qww
Not Connected
Violet
None
7
Error Out
Blue
Fault Signal 2
8
Error Out
Brown
Fault Signal 1
9
Shield
-
Connected to Common
EagleDrive Lead Wire Assignments
The 0-5 VDC Control Signal In must be within -0.3 to +5.1 VDC or the
motor will be irrepairably damaged.